FAILURE MAP
← Case archive

FA-93213 / EV charging session scheduling / Member archive

Connector session state machine: unplug while charging banks time · case 03

Sessions ended by pulling the cable report too little charging time.

Member previewVariant 3 · 3 implementations · 7 checks per implementation

Case contract

Chronological [t, event] pairs drive states Available, Preparing, Charging, SuspendedEV, Finishing. plug: Available->Preparing. auth: Preparing->Charging. ev_pause/ev_resume toggle Charging/SuspendedEV. stop: Charging or SuspendedEV->Finishing. unplug: any non-Available state ->Available, counted abrupt from Charging or SuspendedEV. Before handling each event, a Preparing connector whose plug is more than timeout seconds old returns to Available (one timeout). Invalid events are ignored. Return [state, seconds spent in Charging, timeouts, abrupt].

Why this case matters

Depot, workplace and public EV chargers schedule sessions against prices, circuit limits and departure deadlines; a wrong decision silently strands a driver or overloads a feeder.

One recorded failure

Sample boundary fixture

This sample comes from the broken implementation of a controlled reproducer.

Boundary fixtureActualExpectedOutcome
boundary: unplug while charging["Available", 0, 0, 1]["Available", 60, 0, 1]Failed

MEMBER ARCHIVE

The complete case is available to members.

This record includes three runnable implementations, regression fixtures, execution results, and source hashes.