Auxiliary heat releases as soon as DM rises above its start point · case 05

The immersion heater chatters on and off around aux_dm.

Member previewVariant 5 · 3 implementations · 8 checks per implementation

Case contract

Hydronic heat pump degree-minute controller, one sample per minute of [supply_temp, target_supply] in whole F. Degree-minutes DM accumulate supply - target each minute and are clamped to [floor, 100]. The compressor starts when DM <= start_dm and stops when DM >= stop_dm. Auxiliary heat starts when DM <= aux_dm and stops when DM >= start_dm. Decisions use the DM value after this minute's update. Return [DM, compressor, aux] per minute.

Why this case matters

Residential and light-commercial thermostats make these decisions sample by sample; each defect changes equipment calls in a way that shows up as short cycling, comfort complaints or equipment stress.

One recorded failure

Sample boundary fixture

This sample comes from the broken implementation of a controlled reproducer.

Boundary fixtureActualExpectedOutcome
regression: scenario 55[[-15, false, false], [-30, false, false], [0, false, false], [-29, false, false], [-53, false, false], [-80, true, false], [-100, true, false], [-116, true, false], [-135, true, false], [-155, true, true], [-173, true, true], [-191, true, true], [-204, true, true], [-146, true, false], [-81, true, false], [-16, true, false], [45, false, false], [100, false, false], [100, false, false]][[-15, false, false], [-30, false, false], [0, false, false], [-29, false, false], [-53, false, false], [-80, true, false], [-100, true, false], [-116, true, false], [-135, true, false], [-155, true, true], [-173, true, true], [-191, true, true], [-204, true, true], [-146, true, true], [-81, true, true], [-16, true, false], [45, false, false], [100, false, false], [100, false, false]]Failed