FA-92638 / HVAC thermostat control / Member archive
Averaging holds a stale value when no occupied room is valid · case 03
With everyone out of the occupied rooms the thermostat stops tracking temperature.
Case contract
Thermostat with remote room sensors; each sample is a list of [room, reading tenths F or None, occupied]. Readings outside 32.0-100.0 F or None are invalid. The control temperature is the mean of valid readings from occupied rooms, or of all valid readings if no occupied room has one, rounded half up to a tenth; if nothing is valid the previous control temperature is held (None initially). Return the control temperature per sample.
Why this case matters
Residential and light-commercial thermostats make these decisions sample by sample; each defect changes equipment calls in a way that shows up as short cycling, comfort complaints or equipment stress.
One recorded failure
Sample boundary fixtureThis sample comes from the broken implementation of a controlled reproducer.
| Boundary fixture | Actual | Expected | Outcome |
|---|---|---|---|
| regression: scenario 1 | [722, 688, 728, 728, 686, 734, 734, 722, 686, 790] | [722, 688, 728, 771, 686, 734, 708, 722, 686, 790] | Failed |