FA-92520 / HVAC thermostat control / Member archive
Setpoint limits are only enforced in one display unit · case 05
Switching to Celsius lets the user walk the setpoint outside 45-90 F.
Case contract
Thermostat setpoint keypad. The setpoint is stored in tenths F. In C mode the display shows the stored value converted to C and rounded half up to 0.5 C; a press moves the displayed value by 0.5 C and stores exactly 320 + half_degrees*9 tenths F. In F mode the display rounds half up to whole F and a press moves the whole-degree value by 1 F. After each press the stored value is clamped to 45.0-90.0 F. Return [display, stored_tenths_F] per press.
Why this case matters
Residential and light-commercial thermostats make these decisions sample by sample; each defect changes equipment calls in a way that shows up as short cycling, comfort complaints or equipment stress.
One recorded failure
Sample boundary fixtureThis sample comes from the broken implementation of a controlled reproducer.
| Boundary fixture | Actual | Expected | Outcome |
|---|---|---|---|
| regression: scenario 9 | [["7.5", 455], ["7.0", 446], ["6.5", 437], ["7.0", 446], ["6.5", 437], ["7.0", 446]] | [["7.5", 455], ["7.0", 450], ["7.0", 450], ["7.5", 455], ["7.0", 450], ["7.5", 455]] | Failed |
MEMBER ARCHIVE
The complete case is available to members.
This record includes three runnable implementations, regression fixtures, execution results, and source hashes.
Member access is invitation-based. Sign in with your invited account to inspect the sources.
Sign in to the archive ↗