FA-92507 / HVAC thermostat control / Member archive
Celsius display prints the half-degree digit as 1 · case 02
A setpoint of 22.5 C is displayed as 22.1 C.
Case contract
Thermostat setpoint keypad. The setpoint is stored in tenths F. In C mode the display shows the stored value converted to C and rounded half up to 0.5 C; a press moves the displayed value by 0.5 C and stores exactly 320 + half_degrees*9 tenths F. In F mode the display rounds half up to whole F and a press moves the whole-degree value by 1 F. After each press the stored value is clamped to 45.0-90.0 F. Return [display, stored_tenths_F] per press.
Why this case matters
Residential and light-commercial thermostats make these decisions sample by sample; each defect changes equipment calls in a way that shows up as short cycling, comfort complaints or equipment stress.
One recorded failure
Sample boundary fixtureThis sample comes from the broken implementation of a controlled reproducer.
| Boundary fixture | Actual | Expected | Outcome |
|---|---|---|---|
| regression: celsius off-grid start | [["21.1", 707], ["22.0", 716]] | [["21.5", 707], ["22.0", 716]] | Failed |