FA-92498 / HVAC thermostat control / Member archive
A temporary hold set during a permanent hold becomes permanent · case 03
Pressing the arrows during a vacation hold makes the new setpoint stick past the next period.
Case contract
Thermostat hold logic; samples are [schedule_period_id, scheduled_setpoint, action] where action is None, "resume", ["temp", sp] or ["perm", sp]. A hold setpoint is clamped to 50.0-90.0 F (500-900 tenths). A temporary hold lasts until the schedule period id changes from the one in which the hold was set; a permanent hold lasts until resume. A new hold of either kind replaces the current hold. Return the effective setpoint per sample.
Why this case matters
Residential and light-commercial thermostats make these decisions sample by sample; each defect changes equipment calls in a way that shows up as short cycling, comfort complaints or equipment stress.
One recorded failure
Sample boundary fixtureThis sample comes from the broken implementation of a controlled reproducer.
| Boundary fixture | Actual | Expected | Outcome |
|---|---|---|---|
| regression: scenario 29 | [600, 841, 841, 841, 841, 841, 875, 875, 875, 698, 698, 698, 580, 580, 699] | [600, 841, 841, 841, 841, 841, 875, 600, 600, 698, 698, 698, 580, 580, 699] | Failed |