FA-70928 / Weather index computation / Member archive
Humidex with discomfort band: saturated air acceptance · case 03
Foggy saturated air with dew point equal to temperature returns no humidex.
Case contract
Input air temperature and dew point in degC. If dew point exceeds air temperature return None. e = 6.11*exp(5417.7530*(1/273.16 - 1/(273.15+Td))); H = T + 0.5555*(e - 10); report the humidex rounded half up to an integer and a band on that integer: <30 comfortable, 30-39 some discomfort, 40-45 great discomfort, 46-53 dangerous, >=54 heat stroke imminent.
Why this case matters
Summer heat bulletins publish humidex with a discomfort band.
One recorded failure
Sample boundary fixtureThis sample comes from the broken implementation of a controlled reproducer.
| Boundary fixture | Actual | Expected | Outcome |
|---|---|---|---|
| air 20 C dew point 20 C | null | [28, "comfortable"] | Failed |
MEMBER ARCHIVE
The complete case is available to members.
This record includes three runnable implementations, regression fixtures, execution results, and source hashes.
Member access is invitation-based. Sign in with your invited account to inspect the sources.