Pedestrian walk and clearance timing: the flashing dont walk interval is truncated · case 05
Pedestrian walk and clearance timing returns a wrong result when the flashing dont walk interval is truncated.
Case contract
Input {crossing_ft, walk_speed_tenths (ft/s*10), min_walk, yellow_tenths, red_tenths, min_green, ped_call, split}. FDW = ceil(crossing*10/speed). Walk starts at min_walk and is extended so that walk + FDW >= ceil((crossing + 6)/3.0) (pushbutton-to-far-curb check at 3.0 ft/s). FDW may overlap yellow and all-red, so with a ped call the vehicle green is max(min_green, ceil(walk + FDW - (yellow+red))). Without a call green = min_green. fits is green + yellow + red <= split. Return {walk, fdw, green, fits}.
Why this case matters
Signal timing arithmetic is exact and integer or rational; a wrong rule silently produces unsafe or inefficient timing plans.
One recorded failure
Sample boundary fixtureThis sample comes from the broken implementation of a controlled reproducer.
| Boundary fixture | Actual | Expected | Outcome |
|---|---|---|---|
| timing oracle 0 | {"fdw": 18, "fits": true, "green": 19, "walk": 6} | {"fdw": 19, "fits": true, "green": 19, "walk": 5} | Failed |