Secured floor car call access: credential freshness · case 05
A card read long ago still authorises secured calls, or a call at exactly 10 s is refused.
Case contract
Restricted floors are secured during [lo, hi) hours of day (hour = t//3600 mod 24; when lo > hi the window wraps midnight). A car call to a secured floor is accepted only within 10 s of a card read whose card allows that floor; the credential is consumed by the call it authorises. Unsecured calls are accepted without affecting the credential. Log read, accepted or denied.
Why this case matters
Lift group controllers make these decisions many times per minute; a wrong answer strands passengers, wastes trips or overrides a safety rule.
One recorded failure
Sample boundary fixtureThis sample comes from the broken implementation of a controlled reproducer.
| Boundary fixture | Actual | Expected | Outcome |
|---|---|---|---|
| regression: call eleven seconds after the read | ["read", "accepted"] | ["read", "denied"] | Failed |