FA-67564 / Elevator dispatch scheduling / Member archive
Fire service phase I recall: recall floor choice · case 04
Cars are recalled to a smoke-filled floor.
Case contract
The recall floor is the designated floor unless smoke is detected there and not at the alternate floor. Each car: stationary at the recall floor -> open; stationary elsewhere -> travel to recall; moving towards the recall floor (strictly) -> nonstop to it; otherwise (moving away, or passing the recall floor) -> reverse after stopping at the next floor in its direction, clipped to 0..top.
Why this case matters
Lift group controllers make these decisions many times per minute; a wrong answer strands passengers, wastes trips or overrides a safety rule.
One recorded failure
Sample boundary fixtureThis sample comes from the broken implementation of a controlled reproducer.
| Boundary fixture | Actual | Expected | Outcome |
|---|---|---|---|
| regression: smoke at both recall floors | {"cars": {"L1": ["travel", 5]}, "recall": 5} | {"cars": {"L1": ["travel", 0]}, "recall": 0} | Failed |