FAILURE MAP
← Case archive

FA-67093 / Railway interlocking logic / Member archive

Movement authority end computation: blocking section boundary · case 03

The authority extends through the blocking section.

Member previewVariant 3 · 3 implementations · 8 checks per implementation

Case contract

Sections have lengths and states locked, occupied or unlocked; the train front is offset_m into section train_sec (which it occupies itself). Scan the following sections; the end of authority is the start of the first section that is not locked (reason = its state) or the end of the last section (end-of-route). If that exceeds max_ma_m ahead of the train front, the authority is cut to front + max_ma_m (reason max-length). The margin is subtracted from the end except for a max-length cut.

Why this case matters

Interlocking logic decides whether trains may be given authority; a wrong decision at this point either grants unsafe movements or strands traffic.

One recorded failure

Sample boundary fixture

This sample comes from the broken implementation of a controlled reproducer.

Boundary fixtureActualExpectedOutcome
regression: cap exactly at the obstacle{"eoa_m": 1000, "reason": "max-length"}{"eoa_m": 975, "reason": "occupied"}Failed

MEMBER ARCHIVE

The complete case is available to members.

This record includes three runnable implementations, regression fixtures, execution results, and source hashes.

Member access is invitation-based. Sign in with your invited account to inspect the sources.