FA-66975 / Railway interlocking logic / Member archive
Axle counter section supervision: sweep completion · case 05
The preparatory state ends before the sweep train has left the section.
Case contract
An axle-counter section counts axles in and out. Counting out below zero latches disturbed (count forced to 0). A reset is accepted only when the section is disturbed or the count is non-zero; it zeroes the count and enters preparatory state, which ends only when a sweep train has counted in and the count returns to zero on an out-count. query reports disturbed, prep, occupied (count>0) or clear, in that precedence.
Why this case matters
Interlocking logic decides whether trains may be given authority; a wrong decision at this point either grants unsafe movements or strands traffic.
One recorded failure
Sample boundary fixtureThis sample comes from the broken implementation of a controlled reproducer.
| Boundary fixture | Actual | Expected | Outcome |
|---|---|---|---|
| regression: reset of a miscounted section | ["prep", "occupied", "clear"] | ["prep", "prep", "clear"] | Failed |
MEMBER ARCHIVE
The complete case is available to members.
This record includes three runnable implementations, regression fixtures, execution results, and source hashes.