FAILURE MAP
← Case archive

FA-64342 / Clinical triage scoring / Member archive

Aggregate early warning score with oxygen scale: new confusion scoring · case 02

A newly confused patient responding to voice is scored as alert.

Member previewVariant 2 · 3 implementations · 11 checks per implementation

Case contract

Input {rr, spo2, on_o2, scale2, temp (1 dp), sbp, hr, avpu}. Toy points: RR <=8:3, 9-11:1, 12-20:0, 21-24:2, >=25:3. SpO2 scale 1: <=91:3, 92-93:2, 94-95:1, >=96:0. Scale 2: <=83:3, 84-85:2, 86-87:1, 88-92:0, and >=93 scores 0 on air but on oxygen 93-94:1, 95-96:2, >=97:3. Oxygen +2. Temp <=35.0:3, 35.1-36.0:1, 36.1-38.0:0, 38.1-39.0:1, >=39.1:2. SBP <=90:3, 91-100:2, 101-110:1, 111-219:0, >=220:3. HR <=40:3, 41-50:1, 51-90:0, 91-110:1, 111-130:2, >=131:3. AVPU "A" 0, any other (C new confusion, V, P, U) 3. Risk: total >=7 HIGH, >=5 MEDIUM, else LOW_MEDIUM if any single parameter scores 3, else LOW. Return {score, risk}.

Why this case matters

Aggregate early warning scores drive escalation; each parameter table, the oxygen scale switch and the single-parameter trigger are separate failure points.

One recorded failure

Sample boundary fixture

This sample comes from the broken implementation of a controlled reproducer.

Boundary fixtureActualExpectedOutcome
new confusion scores three{"risk": "LOW", "score": 2}{"risk": "MEDIUM", "score": 5}Failed

MEMBER ARCHIVE

The complete case is available to members.

This record includes three runnable implementations, regression fixtures, execution results, and source hashes.

Member access is invitation-based. Sign in with your invited account to inspect the sources.

Sign in to the archive ↗